PCS2REXA_a112_chgInputVDropTooHigh

During the ac charging, the measured rms voltage across the lines has decreased below the high impedance detection RMS voltage threshold when compared to the RMS voltage at the start of AC charging.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Charging stopped due to large voltage drop
Remove extension cords / Have wiring inspected

Impact

AC charging functionality may be limited or paused

Description

During the ac charging, the measured rms voltage across the lines has decreased below the high impedance detection RMS voltage threshold when compared to the RMS voltage at the start of AC charging.

Cause

The root mean squared (RMS) voltage across the lines has decreased below the high impedance detection RMS voltage threshold

Clear condition

The root mean squared (RMS) voltage across the lines has no longer decreased below the expected RMS voltage threshold

Models

Cybertruck

Visibility

customer, service