DPB_a099_ecuEnContinuousError

Continuous monitor of enable lines detected a missing(low) enable signal.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Power braking assist reduced
Braking may require increased effort

Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Description

Continuous monitor of enable lines detected a missing(low) enable signal.

Cause

Interruption or short to GND of a monitored ECU internal enable line. After the failsafe logic test has finished the ECU internal enable lines are monitored. It is expected that the enable lines always stay at high level (except the SW intends another state). If this is not the case this fault is logged.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Models

Model Y 2025+

Visibility

customer, service-fix