CP_w084_proxPeDisconnected_gb

The charge port (CP) electronic control unit (ECU) detects that the GB DC or AC protective earth (PE) busbar is missing.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

GB DC charging does not start.

Description

The charge port (CP) electronic control unit (ECU) detects that the GB DC or AC protective earth (PE) busbar is missing.

Cause

The CP ECU detects that GB AC proximity voltage is greater than 4.75V for more than 100ms.

Clear condition

The CP ECU detects that proximity voltages for both the GB AC and GB DC inlets are within the nominal cable disconnected range for more than 200ms.

Models

Model S 2012-2020, Model X 2015-2020