CP_a102_wcOvertempFault

The Gen 2 Wall Connector reports a high temperature at which charging should stop.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Unable to charge - Wall connection too hot
Outlet or Wall Connector wiring must be checked

Impact

AC charging is unavailable.

Description

The Gen 2 Wall Connector reports a high temperature at which charging should stop.

Cause

The Gen 2 Wall Connector reports a temperature greater than 90 degrees C.

Clear condition

The CP ECU detects that the charge cable was unplugged.

Models

Cybertruck, Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+, Semitruck

Visibility

customer, service