BMS_f146_SW_Brick_Overdischarged

The battery management system (BMS) has detected that a brick is over-discharged.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Service is required
Schedule service

Impact

Inability to charge, drive, or support the low voltage (LV) system

Description

The battery management system (BMS) has detected that a brick is over-discharged.

Cause

The BMS detects that a brick voltage measured below the minimal threshold.

Clear condition

The BMS detects that a brick voltage measured above the minimal threshold.

Models

Model S 2012-2020, Model X 2015-2020

Visibility

customer, service-fix