The battery management system (BMS) detects an out-of-bounds module voltage reference.
<0.01% (Extremely rare)
Unable to charge
Service is required
This alert is primarily informational. Other BMB voltage signals will be substituted given the reference voltage is unreliable.
The battery management system (BMS) detects an out-of-bounds module voltage reference.
Any battery monitoring board (BMB) reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage.
All BMB reference voltages continuously remain within the in-bounds threshold of the nominal voltage.
Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+
customer, service-fix