BCFALCP_a170_upperFrontOverTemp

The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.

Description

The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).

Cause

Section actuator temperature model has exceeded 100.0 deg C (212 deg F).

Clear condition

Section actuator model estimate has cooled down to a temperature of 85.0 deg C (185.0 deg F).

Models

Model X 2021+

Visibility

service