VCREAR_a201_prechargeFailed

The Rear Vehicle Controller (VCREAR) precharge circuit did not raise the voltage to the target voltage in the expected amount of time.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

The load being precharged may not turn on. Vehicle functions relying on the load being precharged may not operate as expected.

Description

The Rear Vehicle Controller (VCREAR) precharge circuit did not raise the voltage to the target voltage in the expected amount of time.

Cause

The load voltage does not meet the power source voltage in the expected amount of time.

Clear condition

The desired power feed is no longer requested or VCREAR is reset.