VCLEFT_a142_eFuseManagementContinuous16V

Unexpected voltage seen on continuous device outputs.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

Electrical loads for Hydraulic Control Unit (HCU) Electronic Stability Program (ESP) Anti-lock Braking System (ABS) wake line, 1st row seat backrest ventilation fan, 1st row seat cushion ventilation fan, spare (frunk, console, side) High-Side Drivers (HSDs), frunk emergency release switch LED, footwell LED, and B-pillar camera heater may be unavailable.

Description

Unexpected voltage seen on continuous device outputs.

Cause

Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven

Clear condition

Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.

Models

Cybertruck

Visibility

service