The front vehicle controller (VCFRONT) detects the pump 1 eFuse for the powertrain (PT) pump and condenser fan is open (tripped), interrupting electrical power supply to the PT pump and condenser fan. HVAC cabin cooling (air conditioning) and powertrain performance will be limited.
<0.01% (Extremely rare)
None displayed
The PT pump and condenser fan will be unavailable. HVAC cabin cooling (air conditioning) and powertrain performance will be limited.
The front vehicle controller (VCFRONT) detects the pump 1 eFuse for the powertrain (PT) pump and condenser fan is open (tripped), interrupting electrical power supply to the PT pump and condenser fan. HVAC cabin cooling (air conditioning) and powertrain performance will be limited.
A condition detected by the pump 1 eFuse has caused the powertrain pump and condenser fan eFuse circuit to open (trip).
The pump 1 eFuse no longer detects a condition causing the PT pump and condenser fan eFuse circuit to open (trip).
Cybertruck, Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+