VCBATT_a191_exitDriveLowLVBusVoltage

An issue with the low voltage (LV) electrical system requires the vehicle to come to a stop immediately. The vehicle should enter graceful power-off (GPO) to exit drive, and a separate alert should indicate that condition.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Electrical system power reduced
Vehicle shutting down

Impact

The vehicle will not enter drive. If the vehicle is driving, it will exit drive through graceful power-off (GPO) to come to a stop immediately. A separate alert should be present to indicate the GPO

Description

An issue with the low voltage (LV) electrical system requires the vehicle to come to a stop immediately. The vehicle should enter graceful power-off (GPO) to exit drive, and a separate alert should indicate that condition.

Cause

Lead acid: Low voltage (LV) battery voltage below threshold for 3 seconds (3s); transistor gating LV battery connection is open (no current flow); vehicle load shedding is active; or reverse battery transistor issue detected.

Clear condition

Low voltage (LV) battery voltage above threshold; transistor gating LV battery connection is closed; no reverse battery transistor issue detected; vehicle loadshedding is not active.

Models

Model S 2021+, Model X 2021+

Visibility

customer, service-fix