SDCR_a008_hvlinkMIA

HVLINK messages are not being received by secondary disconnect controller (SDC).

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

Active discharge control by SDC may be forced ON.

Description

HVLINK messages are not being received by secondary disconnect controller (SDC).

Cause

At least one message from HVLINK consumed by SDC is not received.

Clear condition

All HVLINK messages consumed by SDC are received.

Models

Cybertruck, Model 3 2017-2023, Model 3 2024+, Model Y, Model Y 2025+

Visibility

service-fix