PCS_a070_chgPfcLineDvdt

The onboard charger input voltage measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected and sudden drop or spike in the measured voltage has occurred, and it is frequently associated with a condition affecting the supply voltage from the AC grid.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

Reduced AC charge rate.

Description

The onboard charger input voltage measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected and sudden drop or spike in the measured voltage has occurred, and it is frequently associated with a condition affecting the supply voltage from the AC grid.

Cause

The onboard charger AC input voltage changed too much between switching cycles compared to acceptable range.

Clear condition

The onboard charger will restart the affected converter(s) automatically until the maximum number of retry attempts has been reached.

Models

Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+

Visibility

service