PCS_a061_chgVLineRationality

High DC offset present on charger input voltage sensor when voltage is not expected.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

Reduced AC charge rate or inability to AC charge

Description

High DC offset present on charger input voltage sensor when voltage is not expected.

Cause

Charger line voltage sensor DC offset exceeds threshold for more than five seconds

Clear condition

Charger line voltage sensor DC offset is below clear threshold for more than 500ms

Models

Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+

Visibility

service-fix

Want to track your firmware alerts, trips and more?