The Power Conversion System (PCS) detects the initial high voltage (HV) bus voltage is too high to measure capacitance, so it must rely on the maximum possible capacitance value instead for HV bus impedance estimation.
<0.01% (Extremely rare)
None displayed
PCS may underestimate the HV bus impedance.
The Power Conversion System (PCS) detects the initial high voltage (HV) bus voltage is too high to measure capacitance, so it must rely on the maximum possible capacitance value instead for HV bus impedance estimation.
The initial HV bus voltage is too high to measure capacitance, so PCS must use maximum possible capacitance value to estimate HV bus impedance.
The DCDC converter is commanded to shut down or receives a new request to precharge the HV bus.
Cybertruck
service