IBST_a062_MICB6TransferError

iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Power braking assist reduced
Braking may require increased effort

Impact

IBST may not operate as expected.

Description

iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).

Cause

IBST detected SPI transfer to TLE9180 bridge driver ASIC has failed.

Clear condition

iBooster can not recover from this condition. iBooster replacement may be required.

Models

Cybertruck, Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+

Visibility

customer, service-fix