HVBATT_a056_BrickVoltageMia

Indicates valid data is missing for one or more brick voltages.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Unable to charge
Service is required

Impact

Brick voltage data is likely being substituted to replace invalid readings

Description

Indicates valid data is missing for one or more brick voltages.

Cause

One or more brick voltages are continuously detected as invalid

Clear condition

All brick voltages continuously have valid data

Models

Cybertruck

Visibility

customer, service-fix