HVBATT_a017_HsShuntAsicCalNotUsed

The programmed high side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default high side shunt ASIC gain will be used and current measurement accuracy may be reduced.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

The default high side shunt ASIC gain will be used for high voltage (HV) current sensing. High side shunt current measurement accuracy may be reduced.

Description

The programmed high side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default high side shunt ASIC gain will be used and current measurement accuracy may be reduced.

Cause

The stored high side shunt ASIC gain is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored high side shunt ASIC gain is valid and the written gain is within the allowed tolerance.