HVBATT_a014_LsShuntAsicCalNotUsed

The programmed low side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default low side shunt ASIC gain will be used and current measurement accuracy may be reduced.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

The default low side shunt ASIC gain will be used for high voltage (HV) current sensing. Low side shunt current measurement accuracy may be reduced.

Description

The programmed low side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default low side shunt ASIC gain will be used and current measurement accuracy may be reduced.

Cause

The stored low side shunt ASIC gain is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored low side ASIC gain is valid and the written gain is within the allowed tolerance.

Models

Cybertruck

Visibility

service-fix

Want to track your firmware alerts, trips and more?

Sign up for Tessie. Try it free for 14 days. Happiness guaranteed.