The Fast Charge (FC) Electronic Control Unit (ECU) has detected a critical flyback converter unstable fault. The emergency shutdown will be performed for the charging session.
<0.01% (Extremely rare)
Charging adapter fault
Unplug and retry
Charging session may not start or may become interrupted.
The Fast Charge (FC) Electronic Control Unit (ECU) has detected a critical flyback converter unstable fault. The emergency shutdown will be performed for the charging session.
FC ECU detects the flyback voltage slews by more than 10kV over a single 10mS period while the flyback is in the drive state.
FC ECU set the flyback target mode to OFF.
Model S 2012-2020, Model X 2015-2020