FC_a277_GB_posToPcbDeltaLo

The Fast Charge (FC) Electronic Control Unit (ECU) has detected a temperature gap between positive pin and Printed Circuit Board (PCB) below -40deg centigrade, limiting the Direct Current (DC) charge limit to 60A.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

DC charge current is limited to 60A.

Description

The Fast Charge (FC) Electronic Control Unit (ECU) has detected a temperature gap between positive pin and Printed Circuit Board (PCB) below -40deg centigrade, limiting the Direct Current (DC) charge limit to 60A.

Cause

FC ECU has detected a temperature gap lower than -40deg centigrade positive pin and PCB.

Clear condition

Unplug charge handle.

Models

Cybertruck, Model 3 2017-2023, Model 3 2024+, Model S 2021+, Model X 2021+, Model Y, Model Y 2025+