EPASTS_a099_mcdTorqueMismatchFault

This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

EPAS reset. If reset more than 5 times then EPAS full loss of assist.

Description

This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit.

Cause

If the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit. EPAS application motor control diagnostics detected failure (itorque value comparison).

Clear condition

Perform EPAS Software update.

Models

Model Y, Model Y 2025+

Visibility

service-fix

Want to track your firmware alerts, trips and more?