This alert is reported by the ParameterSelectorProvider_R12 (PSP) component when Powerpack (PWP), Common (COM), or ECU parameter selection is not successful.
<0.01% (Extremely rare)
None displayed
EPAS full loss of assist.
This alert is reported by the ParameterSelectorProvider_R12 (PSP) component when Powerpack (PWP), Common (COM), or ECU parameter selection is not successful.
EPAS ECU PowerPack (PWP) ID is not compatible with the given software due to ECU parameter set.
Perform EPAS Software update.
Model Y, Model Y 2025+
service-fix