This alert is reported when the power ratio (actual power divided by nominal power) is less than 70% [Calibratable] due to overheat protection.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

EPAS assist torque is limited due temperature cause.

Description

This alert is reported when the power ratio (actual power divided by nominal power) is less than 70% [Calibratable] due to overheat protection.

Cause

EPAS power ratio (actual power divided by nominal power) is less than 60% and the cause is temperature related.

Clear condition

EPAS power ratio (actual power divided by nominal power) is greater than 70% [Calibratable] or the cause of the current degradation is not temperature related.

Models

Model Y, Model Y 2025+