This alert is reported by the PlatformModeProvider_R12 (PMP) component when rotorSpeed QualityofService is RPS_ERROR or RPS_SUBSTITUTE_VALUE and tolerance time has elapsed.
<0.01% (Extremely rare)
None displayed
EPAS full loss of assist.
This alert is reported by the PlatformModeProvider_R12 (PMP) component when rotorSpeed QualityofService is RPS_ERROR or RPS_SUBSTITUTE_VALUE and tolerance time has elapsed.
EPAS rotor speed QoS is fauly or not reliable for longer than a tolerated time.
QoS of the RotorSpeed is QOS_RPS_NOMINAL_FAULT_TOLERANT or QOS_RPS_NOMINAL.
Model Y, Model Y 2025+