EPASTP_a173_pmpRotorspeedAge

This alert is reported by the PlatformModeProvider_R12 (PMP) component when rotorSpeed QualityofService is RPS_ERROR or RPS_SUBSTITUTE_VALUE and tolerance time has elapsed.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

None displayed

Impact

EPAS full loss of assist.

Description

This alert is reported by the PlatformModeProvider_R12 (PMP) component when rotorSpeed QualityofService is RPS_ERROR or RPS_SUBSTITUTE_VALUE and tolerance time has elapsed.

Cause

EPAS rotor speed QoS is fauly or not reliable for longer than a tolerated time.

Clear condition

QoS of the RotorSpeed is QOS_RPS_NOMINAL_FAULT_TOLERANT or QOS_RPS_NOMINAL.

Models

Model Y, Model Y 2025+

Visibility

service-fix