This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit.
<0.01% (Extremely rare)
None displayed
EPAS reset. If reset more than 5 times then EPAS full loss of assist.
This alert is reported by the MotorControlDiagnostics_R12 (MCD) component if the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit.
If the absolute reference torque is greater than the absolute requested torque plus diagnostic limit, or they have opposite signs and the difference is greater than the limit. EPAS application motor control diagnostics detected failure (itorque value comparison).
Perform EPAS Software update.
Model Y, Model Y 2025+
service-fix