This alert is reported by the PWMDriverCD_TC3x component when the control cycle and tasking cycle synchronization mismatch.
<0.01% (Extremely rare)
None displayed
EPAS reset. If reset more than 5 times then EPAS full loss of assist.
This alert is reported by the PWMDriverCD_TC3x component when the control cycle and tasking cycle synchronization mismatch.
EPAS application component PWM monitor detected failure (control cycle and tasking cycle synchronization mismatch).
EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.
Model Y, Model Y 2025+