EGGRIGHT1_a121_eFuseManagementNonContinuous48V

Unexpected voltage seen on non-continuous device outputs.

Live incidence rate

<0.01% (Extremely rare)

Vehicle messages

Powered frunk functions limited
Electrical issue - Schedule service soon

Impact

Electrical loads for frunk strut and frunk motor control may be unavailable.

Description

Unexpected voltage seen on non-continuous device outputs.

Cause

Voltage is above 35V for 10 seconds on at least one of the device outputs while none of them are being driven

Clear condition

Voltage is below 35V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.